The purpose of this Article is to ensure adequate and well-designed parking and loading areas are provided in all districts at the time of erection, enlargement or change in use, of any principal building or lot. Off-street parking and loading areas are to be designed, maintained and operated in a manner that will ensure their efficient use, promote public safety, improve aesthetics and, where appropriate, protect surrounding uses from undesirable impacts. Off-street parking spaces, in conjunction with all land or building uses, shall be provided prior to the issuance of a certificate of occupancy as hereinafter prescribed.

The following standards shall be used in determining the required number of parking spaces:

The minimum number of off-street parking spaces shall be determined by the type of use in accordance with the following schedule:

Parking Space Numerical Requirements

Residential

Mobile or Manufactured Homes in a Mobile Home or Manufactured

Housing Park

2.0 spaces per dwelling unit plus 5.0 additional spaces for any office or clubhouse facility, plus 1 visitor space for every 3 homes Multiple-family Dwellings 1.5 spaces per each efficiency or one-bedroom dwelling unit, 2.0 spaces per each unit with two bedrooms, 2.5 spaces per each unit with three or more bedrooms, plus 5.0 additional spaces for any office, plus 1.0 space per 200 sq. ft. of GFA of any clubhouse facility, plus visitor off-street parking equal to at least 20% of the total spaces required Single- & two-family dwellings 2.0 spaces per dwelling unit Housing for the Elderly Congregate, Assisted Living or Interim Care Housing 1.0 space per each room or three beds, whichever is less,

Dependent Housing Facilities

including convalescent homes, nursing homes, rest homes, etc. 1.0 space per each four beds or two rooms, whichever is less, Senior Apartments 1.0 spaces per unit Institutional/Public Adult & Child Care Facilities 1.0 space per 400 sq. ft. of GFA, plus 1.0 space per employee, plus adequate drop-off area Auditoriums, Assembly Halls, Stadiums and Sports Arenas with

Fixed Seating

1.0 space per each three seats or six lineal feet of bleachers Churches, Temples & Other Places of Worship or Public Assembly 1.0 spaces per each three seats or six feet of pews in the main unit of worship, plus required spaces for any accessory uses

Parking Space Numerical Requirements

such as a school, childcare center, recreation facilities, etc.

Community Centers Including

Senior Centers, Cultural Centers &

Teen Centers

1.0 space per each 250 sq. ft. of GFA, or 1.0 space per every four persons of capacity authorized by the Uniform Building Code, plus 1.0 space per employee, whichever is greater Group Day-care Homes, Adult Foster Care Group Homes, & Adult

Congregate Care Facilities

1.0 space per four residents, plus 1.0 space per employee, plus adequate drop-off spaces Hospitals, Outpatient Service Centers, Urgent Care Centers, Emergency Medical Stations &

Similar Uses

1.0 space per 175 sq. ft. of GFA plus 1.0 space per employee Lodge & Union Halls; Fraternal Orders; Private & Civic Clubs &

Similar Uses

1.0 space per every three persons of capacity authorized by the

Uniform Building Code

Municipal Office Buildings 1.0 space per 250 sq. ft. of GFA Post offices, Public Libraries,

Museums

1.0 space per 200 sq. ft. of GFA (available for public use) plus spaces for employees and delivery vehicles Public Utility Use 1.0 space per employee Schools, Elementary & Middle

Schools

2.0 spaces per classroom plus 2.0 drop-off spaces per classroom plus spaces required for any assembly hall, auditorium, and/or outdoor arena or athletic fields Schools, High Schools, Colleges, Business & Vocational Schools, &

Technical Training Facilities

2.0 spaces per classroom plus 15.0 student spaces per classroom plus parking required for any assembly hall, auditorium, or outdoor arena

Office

Banks, Credit Unions, Savings &

Loans

1.0 space per 200 sq. ft. of GFA, plus 2.0 spaces per each 24-hour teller, plus 4.0 stacking spaces for the first drive-through window and 2.0

Parking Space Numerical Requirements

stacking spaces for each additional drive-through lane Business Offices & Professional

Services

1.0 space per 300 sq. ft. of GFA Medical and Dental Clinic/Offices (where such use comprises at least 50% of the building or site) 1.0 space per 150 sq. ft. of GFA Veterinary Offices, Clinics or

Hospitals

1.0 space per 250 sq. ft. of GFA.

Commercial

Animal Grooming Establishments 1.0 space per 300 sq. ft. of GFA plus 1.0 space per employee Appliance Stores 1.0 space per 250 sq. ft. of GFA Automobile Gasoline Stations 1.0 spaces per each pump island and service bay (bay can be included as a space), plus 1.0 space per employee, plus plus 1.0 space for each 500 sq. ft. of GFA devoted to sales of automotive goods, plus required spaces for any convenience store (mini-mart), restaurant or auto wash Automobile & Vehicle Service Centers & Auto Repair

Establishments

3.0 spaces for each service bay (bay can be included as a space), plus 1.0 space per employee, plus 1.0 space for each tow truck. plus 1.0 stacking space per bay Automobile & Vehicle Dealerships Including Recreational Vehicles, Boats, Motorcycles, & Mobile

Homes

1.0 space per 400 sq. ft. of GFA of interior sales space plus 1.0 space per 600 sq. ft. of GFA of exterior display, plus 3.0 spaces per each service bay (bay can be included as a space)

Parking Space Numerical Requirements

Automobile Washes (Automatic) 2.0 spaces, plus 1.0 space per employee, plus 12.0 stacking spaces per bay for free-standing washes, 6.0 stacking spaces when accessory to a gas station Automobile Washes (Self-service or

Coin Operated)

2.0 spaces per bay for drying, plus 3.0 stacking spaces per wash bay Bars, Taverns, Lounges, and Brewpubs (majority of sales consist of alcoholic beverages) 1.0 space per 75 sq. ft. of GFA Barber Shops, Beauty Salons, and

Tanning Facilities

1.0 space per 175 sq. ft. of GFA or 2.5 spaces per each barber or beautician's chair/station, whichever is greater Bookstores 1.0 space per 200 sq. ft. of GFA Business & Personal Service

Establishments

1.0 space per 300 sq. ft. of GFA plus 1.0 space per employee Conference, Meeting or Banquet Rooms; Exhibit Halls & Similar Uses 1.0 space per every two persons of capacity authorized by the

Uniform Building Code

Convenience Stores (Mini-marts), with or Without Gasoline Service 1.0 space per 250 sq. ft of GFA, plus spaces required for automobile gasoline stations plus 2.0 stacking spaces Discount Stores & Department

Stores

1.0 space per 200 sq.ft. of GFA Dry Cleaners 1.0 space per 500 sq. ft. of GFA plus 2.0 stacking spaces per drop off station Equipment Repair Establishments 1.0 space per 800 sq. ft. of GFA Funeral Homes & Mortuary

Establishments

1.0 space per 50 sq. ft. of GFA of service parlors, chapels and reception area, plus 1.0 space per each funeral vehicle stored on the premises Furniture, Carpet & Flooring Stores 1.0 space per 500 sq. ft. of GFA

Parking Space Numerical Requirements

General Retail & Service Uses Not

Otherwise Specified

1.0 space per 200 sq. ft. of GFA Grocery Store & Retail Food

Establishments

1.0 space per 250 sq. ft. of GFA Hardware, Paint & Home

Improvement Stores

1.0 space per 200 sq. ft. of GFA including outdoor sales space Kennels, Commercial 1.0 space per 400 sq. ft. of GFA, plus 1.0 space per employee Laundromats 1.0 space per each two (2) washing machines, plus 2.0 spaces for employees Marinas 1.0 space per each boat slip during boating season, plus 1.0 space per each five (5) dry-docked boats during the winter season, plus additional access and maneuvering space as determined necessary by the Planning Commission, plus year- round parking spaces as required for other uses such as clubhouse, restaurant or retail store Mini or Self-storage Warehouses minimum of 6.0 spaces Motel, Hotel, Bed & Breakfast Inn, & Similar Uses 1.0 space per guest room, plus 1.0 space per employee, plus 75% of required spaces for restaurants, conference rooms, banquet halls and other uses Open Air Businesses including Nurseries, Garden Centers & Other Outdoor Display, Sales, & Storage

Uses

1.0 space per 500 sq. ft. of GFA of outdoor display, sales and storage area, plus 1.0 space per 200 sq. ft. of GFA of indoor space, plus 1.0 space per employee Pharmacies 1.0 space per 200 sq. ft. of GFA plus 3.0 stacking spaces for any drive-through windows Restaurants, Standard, with Liquor

License

1.0 space per 60 sq. ft. of GFA, or 0.6 spaces per seat, whichever is greater, plus spaces required for any banquet or meeting rooms

Parking Space Numerical Requirements

Restaurants, (Standard, Without Liquor License 1.0 space per 70 sq. ft. of GFA or 0.5 spaces per seat, whichever is greater, plus spaces required for any banquet or meeting Restaurants, Fast Food with Drive- through Window, Including Coffee Shops, Cafes, Delicatessens, etc. 1.0 space per 80 sq. ft. of GFA, plus 10.0 stacking spaces Restaurants, Fast Food Without Drive-through Window 1.0 space per 80 sq. ft. of GFA or 0.5 spaces per seat, whichever is greater Restaurants, Drive-in 1.0 space per drive-in station, plus 1.0 space per employee Restaurant Carry-out & Open Front Window, with fewer than 6 Tables and/or Booths 6.0 spaces plus 1.0 space per employee Showroom of a Plumber, Decorator or Similar Trade 1.0 space per 800 sq. ft. of GFA Shopping Centers with less than 100,000 Sq. Ft. Gross Leasable Floor

Area

1.0 space per 225 sq. ft. of GFA, plus spaces required for any grocery store, bookstore or restaurant, if included Shopping Centers with 100,000 Sq. Ft. or More Gross Leasable Floor

Area

1.0 space per 250 sq. ft, if GFA, plus spaces required for any grocery store, bookstore, or restaurant, if included Studios for Art, Photography, Music, Dance & Similar Uses 1.0 space per 300 sq. ft. of GFA plus 1.0 space per employee Video Rental Establishments 1.0 space per 200 sq. ft. of GFA, with a minimum of 8.0 spaces provided Wholesale Establishments &

Warehouse Clubs

1.0 space per 500 sq. ft. of GFA Recreation/Entertainment

Parking Space Numerical Requirements

Arcades 2.0 spaces per machine plus 1.0 space per employee Baseball & Softball Fields 25.0 spaces per field Batting Cages 3.0 spaces per cage Boat Marinas 1.5 spaces per boat berth, plus required spaces for winter boat storage and other uses Bowling Centers 3.0 spaces per lane, plus 0.5 spaces per seat in spaces designated for any lounge or dining area Golf Course Driving Ranges 1.0 space per tee Golf Courses, Miniature & Par Three 2.0 spaces per each course hole, plus 1.0 space per employee Golf Courses 6.0 spaces per each course hole, plus 1.0 space per employee, plus required spaces for restaurants, banquet rooms, pro shop, offices, and other uses Health Clubs & Fitness Centers 1.0 space per 250 sq. ft. of GFA, plus required spaces for swimming pools, courts, restaurants and other uses Ice/roller Skating Rinks 1.0 space per 170 sq. ft. of GFA, or 1.0 space for each 6.0 seats or feet of bench, whichever is greater, plus 50% of parking required for restaurants, pro shops and other uses Pool & Billiard Halls 1.0 space per 70 sq. ft. of GFA or 1.0 space per every three persons of capacity authorized by the

Uniform Building Code

Recreation Centers (Indoor) Commercial, Not Already Specified 1.0 space per 1,000 sq. ft. of GFA, plus required spaces for restaurants, banquet rooms, offices, sales area, and other uses Recreation Centers (Outdoor) Public or Commercial 1.0 space per 200 sq. ft. of GFA

Parking Space Numerical Requirements

Soccer and Football Fields 30.0 spaces per field Swimming Pools 1.0 space per each three persons of capacity authorized by the BOCA Code Tennis Courts & Racquetball

Centers

1.0 space per 1,000 sq. ft. GFA or 6.0 spaces per court, whichever is greater, plus 50% of required spaces for restaurants, banquet rooms, offices, sales area, & other uses Theaters, Cinemas 1.0 space per each three seats plus 1.0 space per two employees

Industrial

Light Industrial, Manufacturing, Testing Labs, Research, Design &

Development Centers

1.0 space per 700 sq. ft. GFA, or 1.2 spaces per employee, whichever is greater, plus 1.0 space for each corporate vehicle, plus spaces required for any office or sales area Warehousing & Wholesale Establishments (Non-retail) 1.0 space per each 1,500 sq.ft. GFA, or 1.0 space per employee, whichever is greater; plus 1.0 space for each corporate vehicle plus spaces required for any office/sales area

Each parking lot that serves a building or use, with the exception of single and two-family dwelling units, shall provide barrier free spaces in compliance with the State Building Code.

Where required, off-street parking facilities containing more than five (5) parking spaces shall be designed, constructed, and maintained according to the following standards and regulations:

ACCESS

MANAGEMENT

AND DRIVEWAY

STANDARDS

The purpose of this Article is to provide access standards which will facilitate through traffic operations, ensure public safety along roadways, and protect the public investment in the street system; while providing property owners with reasonable, though not always direct, access. The standards are specifically designed for streets whose primary function is the movement of through traffic, as opposed to local streets whose primary function is access to adjacent properties.

and Rear Service Drives

Parking Lot Cross Access. To utilize cross access, an agreement or easement is required from all affected properties.

Driveway Spacing From Other Driveways

Posted Speed (mph) Minimum Driveway Spacing 25 mph 100 feet 30 mph 125 feet 35 mph 150 feet 40 mph 185 feet 45 mph 230 feet 50 mph 275 feet 55 mph 350 feet

and Bypass Lanes

An embedded image (not described)
An embedded image (not described)
An embedded image (not described)
An embedded image (not described)
An embedded image (not described)
An embedded image (not described)
An embedded image (not described)
An embedded image (not described)

1. Frontage roads, rear service drives and drives connecting two (2) or more parking lots shall be constructed in accordance with the following requirements: a. Pavement width shall be a maximum of thirty (30) feet, measured face of curb to face of curb; intersection approaches may be widened to thirty-nine (39) feet for a left turn lane. b. Frontage road access to public streets shall be spaced according to the standards of

1. A tree survey shall be submitted with any site plan for new development. The survey shall identify the location, species and size of existing trees on the proposed site that are to be removed or are within ten (10) feet of the removal area. Existing landmark trees that are planned to be removed shall be replaced on the site in accordance with the following standards: a. Removed landmark trees between eight (8) and eighteen (18) caliper inches shall be replaced at a rate of 50% of the total diameter breast height (dbh). b. Removed landmark trees greater than eighteen (18) caliper inches shall be replaced at a rate of 75% of the total dbh. c. Removed landmark trees greater than thirty (30) caliper inches shall be replaced at a rate of 100% of the total dbh. d. Landmark trees that are dead or diseased, with no visible growth, as determined by the Zoning Administrator, are exempt from replacement requirements.

e. A summary table of existing trees shall be provided, indicating those trees that will be removed. f. Landmark trees are defined by size and species, as listed in the table below:

COMMON NAME SPECIES MINIMUM DBH (INCHES)

American Beech Fagus grandifolia 18 American Chestnut Castanea dentata 8 Birch Betula spp 18 Black Alder Acinus glutinosa 12 Black Tupelo Nyssa sylvatica 12 Black and White Walnut Juglans nigra, J. cinerea 20 Buckeye Aesculus glabra 18 Cedar, Red Juniperus spp 12 Crabapple (cultivar) Malus spp 12 Choke Cherry Prunus spp 18 Douglas Fir Pseudotsuga menziesii 18 Eastern Hemlock Nuga canadensis 12 Flowering Dogwood Cornus florida 8 Hickory Carya spp 18 Horse-chestnut Aesculus camea 18 Kentucky Coffeetree Bymnociadus diocius 18 Larch/Tamarack Larix Laricina (Eastern) 12 London Planetree/Sycamore Plantanus spp 18 Maple Acer spp 18 Oak Quercus spp 16

Pine Pinus spp 18 Sassafras Sassafins albidum 15 Spruce Picea spp 18 Tuliptree Liriodendron tulipfera 18

A separate detailed landscape plan, prepared by a licensed/registered design professional, shall be submitted as part of the site plan review process. 1. The landscape plan shall demonstrate that all requirements of this Article are met and shall: a. Illustrate location, spacing, species, and size of proposed plant material. b. Separately identify compliance with the minimum numeric requirements for greenbelts, buffer zones, parking lot trees, detention ponds, and interior landscaping; required trees or materials cannot be double counted. c. If applicable, identify compliance with the numeric requirements for tree replacement and preservation.

d. Provide, as determined by the Planning Commission, typical cross sections to illustrate views from adjacent land uses and the slope, height and width of proposed berms or landscape elements. e. Identify trees and other landscape elements to be preserved. f. Delineate the location of tree protection fence and limits of grading at the perimeter of areas that to be preserved. g. Provide significant construction details to resolve specific conditions such as limits of grading adjacent to areas with trees and vegetative cover to be preserved, tree wells to preserve existing trees or culverts to maintain natural drainage patterns. h. Provide details to ensure proper installation and establishment of proposed plant material. i. Identify grass areas and other methods of ground cover. j. Identify a landscape maintenance program including a statement that all diseased, damaged or dead materials shall be replaced in accordance with standards of this Ordinance.

c. The use of canopy trees and associated understory are encouraged while walls and berms are discouraged. d. Buffer zones shall include only living materials and planting beds, except for approved sidewalks, bike paths, signs, driveways, and essential services.

Buffer Zone A 1. 30-foot minimum width 2. along the property line with two (2) canopy trees and four (4) shrubs or one (1) canopy tree, one (1) evergreen and four (4) shrubs per twenty (20) linear feet, rounded upward 3. and including a wall, berm or combination of these elements as determined by the Planning Commission Buffer Zone B 1. 10-foot minimum width 2. along the property line with one (1) canopy trees and four (4) shrubs or one (1) evergreen and four (4) shrubs per twenty (20) linear feet, rounded upward

a. Residential adjacent to Residential = Buffer Zone A b. Residential adjacent to all other districts = Buffer Zone B c. Commercial adjacent to Commercial = Buffer Zone A d. Commercial adjacent to all other districts = Buffer Zone B e. Industrial adjacent to Industrial = Buffer Zone A f. Industrial adjacent to Commercial = Buffer Zone B 3. Detention/Retention Pond Landscaping. Ponds shall be located outside required setbacks and designed to provide a natural appearance. Detention and retention ponds shall be provided in accordance with the following standards: a. Side slopes shall be such that the perimeter of the pond shall not need to be fenced. b. The sides of the pond must be undulating to avoid an “engineered” appearance. c. One

landscaping shall be planted in a random pattern, not limited to the top of the pond bank. d. Wild grasses and wetland plantings should be utilized on the side slopes and bottom of the pond to give it a more natural appearance, minimize on-going maintenance, and provide improved filtering of sediments. e. Where a natural landscape is found not to be particular or desirable the Planning Commission may require some type of decorative fencing. 4. Interior Site Landscaping. Site landscaping shall be located near building entrances, along building foundations, along pedestrian walkways, near service areas or as landscaped plazas. 5. Residential and Site Condominium Developments. Landscaping for single-family and multiple-family residential developments shall be provided in accordance with the following requirements: a. Street trees shall be provided at a rate of one

Minimum Sizes and Spacing Type of Plant Material Minimum Plant Sizes Spacing Requirements Deciduous canopy trees 2½ in. caliper 25 ft. on-center Ornamental trees 2 in. caliper 6 ft. height (clump form) 15 ft. on-center Evergreen trees 8 ft. height 15 ft. on-center Narrow evergreen trees 4 ft. height 12 ft. on-center Deciduous shrubs 3 ft. height 4 ft.-6 ft. on-center Upright evergreen shrubs 3 ft. height 3 ft.-4 ft. on-center

Spreading evergreen shrubs 18 in.-24 in. spread 6 ft. on-center

b. Mixing of Species. The overall landscape plan shall not contain more than thirty- three percent (33%) of any one plant species. The use of native species and mixture of trees from the same species association is strongly encouraged. c. Trees Not Permitted. The following trees are not permitted as they split easily, their wood is brittle, their roots clog drains and sewers, and they are unusually susceptible to disease or insects. The Planning Commission may however allow trees from this list when associated with an appropriate ecosystem. Trees not permitted are as follows: Box Elder, Elms, Tree of Heaven, Willows, Soft Maples (silver), Poplars, Horse Chestnut (nut bearing), Ash, Ginkgo (female), Cottonwood, Mulberry, Black Locust, Honey Locust (with thorns). d. Planting Beds. Bark used as mulch shall be maintained at minimum of two (2) inches deep. Planting beds shall be edged with plastic, metal, brick or stone in residential districts and metal edging in all other zoning districts. e. Topsoil. Topsoil shall consist of a 4" base for lawn areas and an 8"-12" base within planting beds. f. Proximity to Utilities. Plant material shall not be located in a manner that will interfere with or cause damage to underground utility lines, public roads or other public facilities. g. Lawn Grasses. Lawn grasses shall be planted in species normally grown as permanent lawns in Tuscola County. Grasses may be plugged, sprigged, seeded or sodded except that rolled sod, erosion reducing net or suitable mulch shall be used in swales or other areas susceptible to erosion and shall be staked where necessary for stabilization. When complete sodding or seeding is not used, nurse grass seed shall be sown and mulched for immediate protection until permanent coverage is achieved. Grass sod and seed shall be free of weeds and noxious pests or disease.

In any case where the building and/or parking area is being increased by at least twenty-five percent (25%) over the originally approved site plan or is being changed to a more intense use as determined by the Planning Commission, the site shall be brought into full compliance with the landscape standards herein. In instances where the increase in building and/or parking area is less than twenty- five percent (25%) over the original site plan, the extent of new landscaping shall be equal to four percent (4%) of compliance for every one percent (1%) of increase in building or parking footprint. For example, a building or parking area increase of ten percent (10%) requires forty percent (40%) compliance with the landscape standards.

SIGNS

1. For each lot or parcel, one non-illuminated sign may be permitted with a gross surface area of four (4) square feet or less and a maximum height of four (4) feet above grade, exclusive of building/house numbers and required traffic control signs. Such sign shall be temporarily or permanently affixed to the ground or permanently attached to the building as a wall sign. For multifamily, single family complexes, and non-residential uses in residential district, an entrance identification sign may be permitted with a gross surface area not to exceed a maximum of thirty (30) square feet and a maximum height of six (6) feet.

Signs erected in any use district by public and private institutions, including but not limited to churches, village, township buildings and schools, shall not exceed forty (40) square feet in area six (6) feet in height, except that if the institution is within a residential district, such sign shall not exceed thirty (30) square feet in gross surface area and six (6) feet in height.

Signs pertaining to the sale, lease, rent, or development of any project requiring a building permit shall adhere to the requirements of the appropriate district. As permanent signs are erected, temporary signs shall be removed so that the total sign area does not exceed the maximum permitted by this ordinance. In no instance shall any temporary sign exceed twenty (20) feet in height above grade.

A sign permit issued by the Zoning Administrator or his/her designated agent shall become null and void if the construction permitted thereon is not commenced within 180 days from the date of issuance. If the work which is authorized by such permit is suspended, a new permit shall first be obtained before construction is again commenced.

Failure to obtain a permit under this article or to pay a required fee, shall subject a sign to removal or subject its owner to fines, as provided for violations of this Zoning Ordinance in Section 20.08.

1. An application for a sign permit under this article shall be made. The application shall have attached the following information: a. Name, address and telephone number of applicants. b. A brief description of the type of proposed sign. c. Location of building, structure or lot to which the sign is to be attached. d. A site plan drawing showing location of all other existing signs and of all other proposed or existing structures showing the sign height, and location of the sign on the site of the property. e. Name and address of the person, firm, corporation, or association erecting or attaching the sign. f. Written consent of the owner of the property on which any sign is to be located. g. A drawing or sketch of the proposed sign, in color, indicating specific dimensions, plan and specifications of the material to be used in its construction, sign colors, lettering and content (copy) to be placed on the sign (the actual typeface style should be approximated), method of illumination, if any, and the method of construction and attachment. h. Where appropriate, details on electrical wiring, with sufficient data to determine if building code or other applicable Village or County codes and regulations are addressed.

After a sign permit is issued, the person erecting, constructing, enlarging, altering or converting a sign shall notify the Zoning Administrator upon completion of the work for which permits were required. All free-standing signs shall also be subject to a footing inspection. All electrical signs shall be subject to a final electrical inspection.

1. Non-signs. The following exceptional displays shall not be considered as signs under this definition: a. Any display of official court or public office notices. b. Awnings or canopies which are completely devoid of any message or symbol. c. Time and temperature displays without any advertising or commercial matter up to a maximum of six (6) square feet providing all clearances prescribed herein for signs similarly located are maintained.

LIGHTING

STANDARDS

The purpose of this Article is to protect the health, safety and welfare of the public by recognizing that buildings and sites need to be illuminated for safety, security and visibility for pedestrians and motorists. To do so, this Article provides standards for various forms of lighting that will: minimize light pollution; maintain safe nighttime driver performance on public roadways; preserve the restful quality of nighttime by eliminating intrusive artificial light and lighting that unnecessarily contributes to “sky glow”; reduce light pollution and light trespass from light sources onto adjacent properties; conservation of electrical energy; and curtail the degradation of the nighttime visual environment.

The standards in this Article shall apply to any light source that is visible from any property line, or beyond, for the site from which the light is emanating. The Village President (or his designee) may review any building or site to determine compliance with the requirements under this Article. Whenever a person is required to obtain a building permit, electrical permit for outdoor lighting or signage, a special land use approval, subdivision approval or site plan approval from the Village, the applicant shall submit sufficient information to enable the Village President to determine whether the proposed lighting will comply with this Article.

The following words, terms and phrases, when used in this Article, shall have the meanings ascribed to them in this section, except where the context clearly indicates a different meaning: Canopy Structure: Any overhead protective structure which is constructed in such a manner as to allow pedestrians/vehicles to pass under.

Flood or Spotlight: Any light fixture or lamp that incorporates a reflector or refractor to concentrate the light output into a directed beam in a particular direction.

Glare: Direct light emitted by a lamp, luminous tube lighting or other light source.

Lamp: The component of the luminaire that produces the actual light including luminous tube lighting.

Light Fixture: The assembly that holds a lamp and may include an assembly housing, a mounting bracket or pole socket, a lamp holder, a ballast, a reflector or mirror, and a refractor or lens. A light fixture also includes the assembly for luminous tube and fluorescent lighting.

Light Pollution: Artificial light which causes a detrimental effect on the environment, enjoyment of the night sky or causes undesirable glare or unnecessary illumination of adjacent properties.

Light Trespass: The shining of light produced by a luminaire beyond the boundaries of the property on which it is located.

Luminaire: The complete lighting system including the lamp and light fixture.

Luminous Tube Lighting: Gas filled tubing which, when subjected to high voltage, becomes luminescent in a color characteristic of the particular gas used, e.g., neon, argon, etc.

Outdoor Light Fixtures: Outdoor artificial illuminating devices, outdoor fixtures, lamps and other similar devices, permanently installed or portable, used for flood lighting, general illumination or advertisement.

Shielded Fixture: Outdoor light fixtures shielded or constructed so that light rays emitted by the fixture are projected below the horizontal plane passing through the lowest point on the fixture from which light is emitted, e.g. “shoebox-type” fixtures. A luminaire mounted in a recessed fashion under a canopy or other structure such that the surrounding structure effectively shields the light in the same manner is also considered fully shielded for the purposes of this Article.

Wall Pack: An unshielded fixture that is typically wall-mounted and used to illuminate a large area.

3) The Planning Commission may approve decorative light fixtures as an alternative to shielded fixtures when it can be proven that there will be no off-site glare and the proposed fixtures will improve the appearance of the site or is necessary for security purposes. 4) The intensity of lighting under roof eaves, awnings, porticos, or other structural projections shall not exceed ten (10) footcandles. The internal illumination of building-mounted awnings is prohibited. 5) Luminous tube, LED, and exposed bulb lighting is prohibited as an architectural detail on all buildings, e.g. along the roof line and eaves, around windows, etc. unless approved by the Planning Commission upon showing that the treatment will enhance the appearance of the building. c. Window Lighting 1) Any light fixtures visible through a window must be shielded to prevent glare at the property line. 2) Luminous tube, LED, and exposed bulb lighting (visible from the property line) is prohibited in the windows of a building unless it is part of a sign that meets the requirements of Article 4, Division 4: Signs. d. Gas Station Canopy Lighting. 1) The intensity of lighting under gas station canopies shall not exceed 32 footcandles or have an average intensity greater than 22 footcandles for LED fixtures. Any other fixtures shall not have an intensity greater than 20 footcandles. 2) All fixtures must be recessed into the canopy and the lens shall not extend below the lowest part of the fixture. e. Other Lighting 1) The internal illumination of building-mounted canopies is prohibited. 2) Indirect illumination of signs and buildings is permitted provided there is no off- site glare. 3) The use of laser light source, search lights or any similar high intensity light for outdoor advertisement or entertainment is prohibited. 4) Lighting shall not be of a flashing, moving, or intermittent type. 5) Luminous tube, LED, and exposed bulb fluorescent lighting is permitted as part of a sign meeting the requirements of Article 4, Division 4, Signs.

The following are exempt from the lighting requirements of this Article, except that the Village President may take steps to eliminate the impact of the exempted items when deemed necessary to protect the health, safety and welfare of the public:

Should any light fixture regulated under this Article, or the type of light source therein, be changed after the permit has been issued, a change request must be submitted to the Village President for approval, together with adequate information to assure compliance with this Ordinance, which must be received prior to substitution.

APPROVAL

PROCEDURES

SITE PLAN

REVIEW